| 工程翻譯是世聯擅長領域,世聯北京翻譯公司承接各類工程翻譯,我公司有專業的工程翻譯譯員,以下就是我公司譯員對室內給水系統進行的翻譯整理。 室內給水系統: 翻譯:Indoor water supply system: 1、本工程生活最高日用水量為193 m3/日(開會時),其中開會時用水量為113 m3/日,汽車用水量46 m3/日,綠化用水量為16 m3/日,不可預見用水量為18 m3/日,空調冷卻水補水量約為26 m3/h。 翻譯:The maximum daily living water demand for this project is 193 m3/day (during conference period), in which, 113 m3/d for conference, 46 m3/d for cleaning cars, 16 m3/d for greening purpose, and unpredictable water demand of 18 m3/d, the make-up cooling water for air conditioning is about 26 m3/h. 2、本工程生活給水由三臺變頻泵供給,枝狀供水。 翻譯:The living water for this project may be supplied in tree-type through three frequency-inverter controlled pumps. 3、本工程殘疾人衛生間的衛生器具配置光控器,其余衛生器具均用銅閥控制。 翻譯:The fixtures for handicapped toilet may be equipped with photoelectric controller, and all other fixtures may be controlled with copper valves. 4、本工程消防設計依據為中華人民共和國頒發的《建筑設計防火規范》修訂本GBJ16-87 2001年版及當地實際情況,室內設計消火栓系統及自動噴水滅火系統。消防系統用水量,室內15L/S,室外30L/S;自動噴水滅火系統30L/S。本工程消火栓全部為單栓、單龍帶暗裝式。消火栓處設報警按扭,屋頂層設試驗消火栓一個,三層設置消防水箱,容積為18m3,并設消防增壓裝置一套。本工程消火栓系統全部為水泵加壓,加壓泵設在制冷機房內,一備一用,室內消火栓下部裝設手提滅火器,滅火器為磷酸銨鹽(NH3)PO4代號為MFA2,本工程自動噴水滅火系統為濕式自動噴水滅火系統,按中Ⅰ危險級設防。濕式自動噴水滅系統裝置,除配餐廚房用93°噴頭外,其余均為68℃噴頭,宴會廳、首腦餐廳采用F1FR-300噴頭,全會會場及主休息廳采用隱蔽噴頭,濕式系統加壓泵為二臺,一備一用,設在制冷機房內,水流指示器按防火分區設置,并設有信號閥。室外設地下式消火栓7處,各消防系統分別設置水泵結合器,其中消火栓系統一座,噴淋系統二座。室內消防管網為環狀供水,并在環狀管網上安裝分段閥門,便于檢修。 翻譯:The fire control design for this project may refer to revised version of GBJ16-87 Codes of Design for Building Fire Control issued in 2001 and combined with local actual conditions, the hydrant system and automatic water-jet extinguishing system adopt the indoor design. The water demand for fire control system is 15L/S indoor and 30L/S outdoor, and 30L/S for automatic water-jet extinguishing system. All hydrants for this project adopt concealed single hydrant and single hose. And the hydrant may be installed with alarm button, and the roof floor shall be equipped with one hydrant for testing; the third floor may be installed with 18m3 fire water tank, and one set of fire water pressurizer. All hydrant systems shall be pressurized through water pump, the pressurizing pumps may be installed in the refrigerator house, one for service and one for standby, under the indoor hydrant, the (NH3)PO4 (code number of MFA2) portable extinguisher shall be installed. The wet-type automatic water-jet extinguishing system may be installed according to requirements of ClassⅠprotection level. Apart from kitchen equipped with 93°sprinkler head, all other wet-type automatic water-jet extinguishing system may adopt 68°sprinkler heads, the banquet hall and special restaurant for senior officers may adopt F1FR-300 nozzle, the plenary meeting place and main retiring hall may adopt concealed nozzle, two wet-type pressurizing pumps, one for service and one for standby, may be installed in refrigerator house, the flowrate indicator may be installed according to the zone division for fire control and equipped with sentinel valve. The outdoor underground hydrants shall be arranged at 7 places, all fire control system shall be equipped with water pump coupling respectively, including one hydrant system, two water-jet systems. The indoor fire water pipeline may adopt the ring-type network and installed the valves in sections, easy to maintain and repair. 如果您有工程翻譯相關的需求,可以隨時與我公司在線客服人員聯系,同時也可以撥打我們的服務熱線:010-64809262,世聯竭誠為您提供優質的翻譯服務。 |